To create and help in creating a quality oriented metrology infrastructure in the region for providing credible inspection, testing and calibration results for the growth of regional trade and industry.

As C.E.O. of Al-Meezan Industrial Metrology Services engaged in setting up a state of the art inspection, testing and calibration set up for the provisioning of accredited calibration services in Pakistan and metrology and QMS consultancy and trainings in Middle East and Pakistan.

IRCA Registered Lead Auditor for ISO 9001:2015 05 Days SGS Academy
ISO/IEC 17025:2005 Standard awareness 02 Days ITQM P.U.
ISO/IEC 17025:2005 Assessor (APLAC TR001) 05 Days PNAC*
ISO/IEC 17025:2005 Method validation & traceability 01 Day PNAC
ISO/IEC 17025:2005 Quality Assurance & Internal cal. 01 Day PNAC
ISO/IEC 17025:2005 Measurement Uncertainty. 02 Days CICM
Internal Auditor course for ISO 9001:2008 05 Days INSPECTEST
Internal Auditor Course for IMS Certification 02 Days DEL Qatar BA
Diploma of Associate Engg (Electronics). 130 Weeks School of Elects.
Calibration of Electronics, Mechanical, Dimensional, Surveying and Process measuring instruments. 13 Weeks F-16 FTD*, PAF
Temperature Measurement. 01 Week Fluke Corp. UK
Safety and Relief Valve Testing 02 Days Ventil BV NL.
Surface Table Calibration System 02 Days Wyler Swiss
Meter Tap and Line Scale Calibration 02 Days General Tech
Pressure Calibration System ADT761 01 Day Anum UAE
Water Distillation Installation & Operation 01 Day Nawaris Medical
Measurement System Analysis (Minitab Software) 02 Days CICM
Technical Instructor Course 04 Weeks No. 107 AED
Quality Assurance and Control 02 Weeks No. 107 AED
On Job calibration training supervisor. 01 Weeks F-16 FTD, PAF
Calibration of spectrophotometers. 08 Weeks F-16 FTD, PAF
Calibration of Test Stands for Turbojet Power Plants. 02 Weeks F-16 FTD, PAF
Calibration of Radar Simulators. 02 Weeks F-16 FTD, PAF

i) May, 2014~July, 2016 Worked at Modern Surveying Calibration Laboratory Kurdistan Iraq as Metrology Supervisor participated for setting up an 1800 square meter with 08 dedicated laboratories, procured, installed and commissioned +200 calibration standard equipment, gave hands on training to around 15 technical staff and managed to get accreditation for around 52 ranges and CMC in 8 parameters.
ii) Aug,2012~May,2014 working as Business Development Manager for “Accutech Instrumentation Services LLC. Set up a calibration lab and got Accreditation for 17025: 2005 from DAC Dubai.
iii) Jan, 2011 ~ April, 2012 working is Manager Calibration Lab at “Gray Mackenzie Engineering Services WLL” Qatar. Actively participated in the growth of cal business.
iv) Jan, 2010 ~ Jan, 2011 working as Incharge Marketing and Quality Assurance at “Gray Mackenzie Engineering Services LLC” Dubai. Got Accreditation for ISO 17025: 2005 for Calibration and Appliance testing from ENAS UAE.
v) Feb, 2008 ~ Jan, 2010 working as incharge Calibration Lab at “Inspectest (pvt) Ltd. Lahore Pakistan. Prepared and implemented QMS & Technical Management system for 17025: 2005 accreditation of the Calibration Laboratory.
vi) May, 1992 ~ Feb, 2008 working as calibration technician, supervisor, technical instructor, quality assurance inspector, on job training coordinator and Lab incharge at “Precision Measurement Equipment Calibration Labs” of Pakistan Air Force.
General Manager

Shahzad Ahmed

Electronics, Digital Electronics, Metrology/Calibration, Lab Competence Assessment as per ISO- 17025:2005 Quality Management, Quality Control and Quality Assurance

  • Setting up of New Calibration Lab At Al Meezan Industrial Metrology Services, Lahore, Pakistan Worked as a business partner and General manager to setup and establish a new calibration lab at Lahore, Pakistan.
  • Setting up of New Calibration Lab At Modern Surviyer Calibration FZE, Erbil Iraq Worked as a member of a team of two Sr. Metrologists to Set up of new Calibration Lab at Erbil, Iraq.
  • Setting up of New & Up graded Calibration Lab At APC & ICentre PCSIR Labs Complex Lahore Worked as a member of a team of three Sr. Metrologists to Set up of new & up graded Calibration Lab at APC&I Centre, PCSIR Labs Complex, Lahore that can fulfill the role of secondary lab in the province of Punjab.
  • Implementation of ISO 9001:2000 Worked as Assistant Quality Manger during 2002-2003 for the development of Quality System documentation regarding Implementation of ISO 9001:2000 at APC & I Centre.
  • Implementation of ISO 17025:2005 Worked as Assistant Quality Manger during 2003-2005 for the development of Quality System Manual Quality System Procedures, Work Instructions, Forms & Records, Control Charts and Related Analysis regarding Implementation of ISO 17025:2005 at APC & I Centre.
  • Dry Block Thermocouple Digital Calibrator Designed and developed a Digital Calibrator for calibration of Thermocouples and temperature sensors.
  • Automatic Temperature Controlled Heating System for Injection Moulding Machine Designed and developed Automatic Temperature Controlled heating system for Injection moulding Machine for M/s Model Sports, Sialkot.
  • Calibration System for Clamp-meters Designed and developed Calibration System for Clamp-meters with calibration range up to 300 A.
  • Calibration System for Meggers Designed and developed Calibration System for Meggers with calibration range up to 2200 M
  • Calibrator for 4 pin Earth Testers Designed and developed Calibrator for 4 pin Earth Testers based on IEEE-80

Accreditation Body Lab Assessed Month & Year
GAC Betalink Instrumentation and Calibration, Abu Dhabi July 2015
PNAC Dimensional Metrology Lab, POF, Wah, Pakistan July 2013
PNAC Calibration Lab, Miraj Rebuild Factory, Kamra, Pakistan July 2013
PNAC Precision Measurement Electrical Lab, 509, Gujranwala, Pakistan June 2013
ENAS EMIS, Intertek, Abu Dhabi, UAE April 2013
ENAS Metromac, Calibration & Automation Services, Abu Dhabi, UAE April 2013
ENAS QCAL, Qatar Calibration & Instrumentation Services, Qatar April 2013
PNAC Calibration Lab, Avionics Production Factory, Kamra, Pakistan January 2013
ENAS Calibration Lab, Rohde & Schwarz, Abu Dhabi, UAE December 2012
ENAS Calibration Lab, Attock Refinery, Rawalpindi, Pakistan February 2011
PNAC Precision Measurement Electrical Lab, 107, Karachi, Pakistan February 2011
ENAS Calibration Lab, Miraj Rebuild Factory, Kamra, Pakistan February 2011
PNAC Calibration Lab, Attock Refinery, Rawalpindi, Pakistan February 2011
ENAS Precision Measurement Electrical Lab, 107, Karachi, Pakistan February 2011
PNAC Calibration Lab, Rohde & Schwarz, Abu Dhabi, UAE February 2011